See the ball in flight.
To DIN EN 12193, at least 100 lx at the tee and 50 lx vertical. So that the ball does not vanish into the dark after a few metres, floodlights shine far into the outfield – for example 10 lx vertical up to 150 m.

Anyone wanting to practise after work in autumn and winter is standing in the dark. With LED floodlighting, the driving range becomes an evening practice ground – along with the practice greens, paths and car park. Instead of basic site floodlights that dazzle and fail every few years, we design an installation that lights evenly, can be controlled and respects its surroundings.
To DIN EN 12193, at least 100 lx at the tee and 50 lx vertical. So that the ball does not vanish into the dark after a few metres, floodlights shine far into the outfield – for example 10 lx vertical up to 150 m.
Even, glare-free light that reveals the line, slope and hole. A few floodlights with timer control are often enough instead of many site floodlights.
The Series 16 street light for the car park, access road and paths to the clubhouse – robust to IP66 and IK08, with optics that put the light on the area.
Precise optics, warm white light, dimming and timer control. The lighting calculation shows in advance how much light reaches neighbouring properties and woodland edges.
The Series 12 LED floodlight delivers up to 170 lm/W, is rated IP66 and IK10, dimmable via 0–10 V and steplessly adjustable in tilt and side angle. Spare parts are available for 10 years after the end of availability – no buying replacements every year, no lights on all night.
If the facility already has masts, they can often be reused; floodlight masts should be structurally checked first. We supply matching new masts; foundations and civil works are carried out by a contractor of your choice.
Which values the standard sets for the tee, how the outfield is lit and what matters for the putting green and surroundings.
Read the guideAim the Series 12 floodlight in 3D and see the light distribution.
OpenCalculate yourselfWhat LED saves compared with your current floodlights.
OpenWe reply personally, usually on the next working day.
To DIN EN 12193, at least 100 lx horizontal and 50 lx vertical at the tee, with a uniformity of 0.8. For the ball flight the outfield is also lit, for example with 10 lx vertical up to 150 m.
Yes. Practice greens are lit evenly and glare-free so that the line, slope and hole are easy to see. A few floodlights with timer control are often enough.
With precise optics, warm white light, dimming and timer control, the light largely stays on the facility. The lighting calculation shows in advance how much light reaches neighbouring properties.
LED floodlights with precise optics, a high protection rating and dimming. They light more evenly, dazzle less, last much longer and can be controlled by opening hours.
TRiALED designs with DIALux to DIN EN 12193 and supplies LED floodlights, street lights and masts from one source. Foundations and civil works are carried out by a contractor of your choice.