Car park, road, access.
Up to 167 lm/W, IP66, IK08, 10 kV surge protection and −40 to +60 °C. Mounted on a pole or bracket arm, with infinitely adjustable tilt.

For outdoor areas, we supply luminaires and poles from one source: the Series 16 street light for car parks, access roads and paths, and the Series 12 floodlight for sports pitches and large areas.
Up to 167 lm/W, IP66, IK08, 10 kV surge protection and −40 to +60 °C. Mounted on a pole or bracket arm, with infinitely adjustable tilt.
Up to 170 lm/W, IP66 and IK10, 20° or 40° optics, dimmable via 0–10 V. Tilt and side angles are infinitely adjustable.
We supply poles to match the luminaire and the area. The height follows from the lighting calculation – usually around 4 to 10 metres in car parks.
DIN EN 12464-2 for car parks and operational areas, DIN EN 13201 for roads, DIN EN 12193 for sports pitches.
We do not carry out foundations, earthworks, cable laying, erecting the poles or installation. For that, you commission a civil engineering or electrical contractor of your choice – we supply the luminaires, poles and the lighting calculation.
If existing poles and cables are in good condition, you often only replace the luminaires. That saves foundations and civil works – often one of the biggest cost items. Floodlight masts should be structurally checked first.
We reply personally, usually on the next working day.
Yes. We supply poles to match the luminaire and the area. Foundations, earthworks, cable laying and installation are carried out by a contractor of your choice.
For car parks, access roads and paths the Series 16 street light; for sports pitches and large areas the Series 12 floodlight with 20° or 40° optics.
Around 4 to 10 metres is usual. The right height depends on the area size, optics, surroundings and glare control and is set in the lighting calculation.
Often yes, if poles and cables are in good condition. Floodlight masts should be structurally checked. This saves the cost of foundations and civil works.
DIN EN 12464-2 states typical maintained values of 5 lx for car parks with light traffic, 10 lx for medium and 20 lx for heavy traffic. Good uniformity is just as important.