Good light helps learning, and schools are ideal for LED: many rooms, fixed hours of use and empty rooms during breaks and holidays. With presence and daylight control, the lights are only on when they are needed – also an important building block for the climate targets of public buildings.

Updated on · 3 min read · TRiALED lighting advice

At a glance
  • For classrooms, DIN EN 12464-1 specifies 300 to 500 lx depending on use, and 500 lx vertical for the board
  • Presence and daylight control saves a particularly large amount in schools
  • School sports halls need ball-impact-resistant luminaires
  • Schools need safety lighting in line with state requirements

Which values apply?

AreaTypical maintained value
Classrooms in primary and secondary schools300–500 lx
Evening classes, adult education, lecture halls500 lx
Wall board500 lx vertical
Corridors100 lx

Guide values to DIN EN 12464-1 and licht.de. The exact values depend on the version of the standard and the use; uniformity, glare and colour rendering (Ra ≥ 80) are always part of it.

Matching luminaires

Light only when someone is there

Classrooms stand empty during breaks, free periods and holidays. Presence detectors then switch the lights off, and daylight sensors dim them when the sun is out. More on this in the guide Presence detectors and light control.

Safety lighting

Schools need safety lighting for escape routes in accordance with the state school building regulations and the fire safety concept. The luminaires of Series 19 test themselves – largely sparing the caretaker the monthly inspection.

ConsultationLet's talk about your project.Lighting calculation and quotation from the manufacturer.Discuss your project

Climate targets and funding

For public buildings, the EU Energy Performance of Buildings Directive tightens the requirements – more in the guide EPBD and lighting. There are regularly funding programmes for municipalities and school authorities; check the current situation before awarding a contract.

LED savings calculatorWhat can your lighting save?Energy costs, CO₂ and payback in just a few minutes.Calculate the saving

Frequently asked questions

How many lux does a classroom need?

Depending on use and the edition of the standard, DIN EN 12464-1 specifies 300 to 500 lx for classrooms and 500 lx vertical for the board.

Are presence detectors worthwhile in schools?

Yes. Classrooms are often empty during breaks, free periods and holidays. Presence and daylight control saves energy there on top of the LED technology.

Does a school need emergency lighting?

Yes, schools generally need safety lighting for escape routes. Exactly what applies follows from the state's school building regulations and the fire safety concept.