How many lux does a football pitch need?
| Class | Typical use | Illuminance | Uniformity |
|---|---|---|---|
| III | Training, local leagues, youth, recreation | 75 lx | 0.5 |
| II | Regional amateur leagues, performance training | 200 lx | 0.6 |
| I | Upper amateur leagues, not televised | 500 lx | 0.7 |
The assignment of leagues is a common guide. Binding are the requirements of your regional football association and, where applicable, your municipality as owner of the pitch. DFB, DFL and UEFA competitions have their own, higher values – they are listed in the next section. The Regionalliga divisions are governed by the regional associations.
DFB, DFL and UEFA requirements: from U19 to the Bundesliga
DIN EN 12193 is the baseline. As soon as a pitch hosts DFB, DFL or UEFA competitions, their requirements apply on top – and some of them are well above the values in the standard.
| Competition | Minimum floodlighting | Basis |
|---|---|---|
| DFB youth league U19 and U17 (DFB-Nachwuchsliga) | 400 lx | DFB implementing provisions, § 63 no. 7 |
| Youth academy (NLZ) of Bundesliga and 2. Bundesliga clubs | One pitch meeting the requirements of the DFB U16 to U19 competitions, i.e. 400 lx; plus, as a rule, two floodlit artificial turf pitches | DFL licensing regulations, annex V |
| UEFA Youth League | 350 lx horizontal, possibly more for TV production | UEFA Youth League regulations art. 30 and 33, UEFA Stadium Infrastructure Regulations art. 16 (category 1) |
| 3. Liga | 800 lx towards the cameras, uniformity 0.6 (min/average) and 0.4 (min/max) | DFB safety guidelines, annex 1 |
| 2. Bundesliga | 1,200 lx vertical towards the cameras | DFL licensing regulations, annex VI art. 16 |
| Bundesliga | 1,600 lx vertical towards the cameras | DFL licensing regulations, annex VI art. 16 |
U19 and U17: The 400 lx required in the DFB youth league are twice the 200 lx of lighting class II. A pitch designed only for class II is therefore not enough for competitive youth league matches.
Youth academies (NLZ): Under annex V of the DFL licensing regulations, a youth academy needs at least three pitches for its exclusive use, four in the highest category. One of them must meet the requirements of the DFB U16 to U19 competitions. As a rule, at least two pitches are floodlit artificial turf pitches; one is enough if there are sufficient floodlit grass pitches. The DFL sets no lux value for the remaining training pitches – here DIN EN 12193 applies, with 75 lx for training and 200 lx for performance training.
UEFA Youth League: Matches are played in UEFA category 1 stadiums or training centres. UEFA requires at least 350 lx horizontal, or as much light as the broadcaster needs for proper coverage. UEFA can set higher values for television and chooses the stadiums for the semi-finals and final itself.
Professional leagues: In the 3. Liga, 2. Bundesliga and Bundesliga, what counts is the vertical illuminance towards the cameras. There are also requirements for backup power, and the official measurement report of the floodlighting must be submitted. For DFB national matches, the installation must also be inspected and cleaned by a specialist company twice a year – before the first and before the second half of the season.
Sources: DFB implementing provisions as of 1 July 2026, DFL licensing regulations with annexes V and VI as of 5 December 2025, UEFA Youth League regulations 2026/27 and UEFA Stadium Infrastructure Regulations in force from 1 June 2025. The associations update their requirements regularly; the current edition always applies.
Uniformity: light right up to the corner flag
A bright centre circle is of little use if the corners are dark. Uniformity states how far the weakest point may fall below the average. At 0.7 it may be no more than 30 % below the average. Old installations with aged lamps often miss this value – even when the average is still right.
Masts and layout
On club pitches the masts usually stand along the long sides – four, six or eight depending on pitch size. The floodlights are aimed so that goalkeepers and players are not dazzled by high balls. A standard pitch measures 105 × 68 m; training pitches and small-sided pitches often manage with fewer masts.
In a retrofit the existing masts usually stay. The structural load needs checking, though: LED floodlights are often lighter than the old metal halide floodlights but have a different wind load area. We check this before quoting.
How many floodlights your pitch needs at which mast height is something you can work out yourself beforehand – in the floodlight planner of our brand DeinFlutlicht. Planning it yourself saves us the design work, and that makes the quote cheaper.
Light on the pitch, not next door
Modern LED floodlights focus the light precisely on the pitch. That reduces light spill into homes and streets and glare for residents. This was a key point in Sondershausen: Series 12 with targeted optics, controlled by remote – and 68 % less lighting energy. More in the Sondershausen case study.
ConsultationLet's talk about your project.Lighting calculation and quotation from the manufacturer.What does LED floodlighting save?
An old installation with 16 floodlights of 2,000 W each runs 600 hours a year: 19,200 kWh.
An LED installation with the same illuminance often needs around 60 % less: about 7,700 kWh.
At €0.30 per kWh that is around €3,450 less in electricity costs a year – before dimming for training.
All figures are assumptions. How much your pitch saves depends on the installation, operating hours and electricity price. A first estimate is provided by the LED savings calculator.
LED savings calculatorWhat can your lighting save?Energy costs, CO₂ and payback in just a few minutes.Frequently asked questions
How many lux does a football pitch need?
Under DIN EN 12193, 75 lx for training and basic matches (class III), 200 lx for mid-level matches such as regional amateur leagues (class II) and 500 lx for high-level competition such as the upper amateur leagues (class I). DFB, DFL and UEFA competitions require higher values, such as 400 lx for U19 teams in the DFB youth league.
How many lux does the U19 need in the DFB youth league?
At least 400 lx. This is laid down in § 63 no. 7 of the DFB implementing provisions to the match regulations for the DFB youth league of A and B juniors, i.e. U19 and U17. The 200 lx of lighting class II are not enough.
Which floodlighting requirements apply to a youth academy (NLZ)?
Under annex V of the DFL licensing regulations, at least one pitch of the youth academy must meet the requirements of the DFB U16 to U19 competitions – for floodlighting that means 400 lx. A youth academy also needs, as a rule, at least two floodlit artificial turf pitches. The DFL sets no lux value for the remaining training pitches; here DIN EN 12193 applies, with 75 lx for training and 200 lx for performance training.
How many lux does the UEFA Youth League need?
The UEFA Youth League is played in UEFA category 1 stadiums or training centres. They require at least 350 lx horizontal illuminance – or as much as the broadcaster needs for proper coverage. For television, UEFA can demand higher values.
How many lux does a stadium need in the 3. Liga, 2. Bundesliga and Bundesliga?
In the 3. Liga, 800 lx towards the cameras with a uniformity of 0.6 (min/average) and 0.4 (min/max), according to the DFB. In the 2. Bundesliga 1,200 lx and in the Bundesliga 1,600 lx vertical towards the cameras, according to annex VI of the DFL licensing regulations. Requirements for backup power apply in addition.
How many lux does a football pitch need for training?
75 lx at a uniformity of 0.5 (lighting class III). For performance training, class II with 200 lx is often planned.
How many floodlight masts does a football pitch need?
Club pitches usually have four, six or eight masts – depending on pitch size, lighting class and mast height. The exact number comes from the lighting calculation.
Can I keep the existing floodlight masts?
Usually yes. Before the retrofit we check the structural load, because LED floodlights have a different weight and wind load area from the old ones.
How much does LED floodlighting save on a football pitch?
At the Sondershausen sports centre, energy demand fell by 68 %. Significant savings are typical, because LED floodlights are more efficient and can be dimmed for training.